Check: Make sure the connection is hand tight but not TOO tight. Make sure there is a bit of space between the outside shoulders of the male/female connection. Not all parts are manufactured to the exact same specifications, so lengths of male fittings and female sockets are not always consistent or compatible. Check: If the male threads are too short when threaded into the female hose fitting to seat against the hose washer, the fitting will leak. Check: Is the washer or 0-ring present? Is it cracked, worn out, or deformed? Is it evenly installed? If there is any question about its reliability replace it and treat with silicon lube (HLUBE) to prolong the life of and help make a water-tight connection. How can I make it stop? Hose thread joints use washers or O-rings, placed in the female side of the connection. I've connected my hose-thread device to my hose bib and it leaks like a sieve at the swivel. Another is to swap out your 2 gph emitters for those with lower flow rates. One solution is to divide that line into two separate zones. What is going on? It sounds like you have too many emitters for the 240 GPH carrying capacity of your 1/2" mainline tubing. My water is clean and I am using a filter. They are supposed to be 2 gallons per hour (gph), but some of them are only dribbling. I have a bunch of emitters on ½" mainline tubing. If the hole still leaks you will need to cut out the leaky portion and insert a coupler that matches your size tubing. How do I fix this? First try a two-sided goof plug (14GP2) which has a standard sized plug on one end and an oversized plug on the other. I had a leaky emitter which I replaced with a goof plug, but it still leaks. We suggest a pressure regulator after the filter.

galcon 2010 ez timer valve

What could be wrong if emitters and fittings won't hold tight and keep coming off? Likely, your pressure is too high.

galcon 2010 ez timer valve galcon 2010 ez timer valve

A water filter is insurance even with "clean" water and a regular cleaning of your filter is recommended. Sounds like a system with a dirty filter or no filter. What could be wrong if less and less water is coming out of my system?. If the leak persists, replace the O-ring or see whether there is another source for the leak. Re-assemble the filter and put it back in service. What if water is leaking from the body of my filter? Open the filter, remove the O-ring, and clean it, the groove it sits in and the surface it mates against. If your flow exceeds those numbers, your supply is being over drafted. Our 1/2" tubing carries 240 gph 3/4" tubing carries 480 gph. Add the maximum flow rates of the water dispensing products on the line. What if water comes out at the beginning of the system but not at the end? There's a good chance you are using more water than your line can carry. Please note that a Galcon DCV solenoid valves will need to be puchased separately.What do I do when a valve won't shut off? See our Valve Troubleshooting Guide.

GALCON 2010 EZ TIMER VALVE SERIES

Galcon DCS series are durable enough to be installed below ground in a valve box providing reliable trouble free control. Galcon DCS series battery operated controller designed for use in watering systems when running wires is not an option. Pipes (Water Pipes, Metric, Rural, Plumbing Fittings, etc.).Pipes, Hoses & Fittings (Poly Pipe Fittings, Irrigation Pipes, PVC Pipes, Etc.).Fittings (Drip Irrigation Fittings, Poly Fittings, etc.).






Galcon 2010 ez timer valve